____________________________________________________________________
External floppy drives cannot be accessed when attached
behind Sentinel Rainbow Key(s) on the parallel port
For example, on Cannon Notebook model INNOVA NOTE 3800FX with key,
2 straight-through cables, and external floppy driver
also on LapTop DELL latitude CP
Solution: if the floppy drive is necessary to use in conjunction
with the key, the external floppy driver can be installed as an
internal driver by exchanging it with the internal CD-ROM drive
while the power is off.
If the solution above is not effective, try to connect the floppy
drive with a PC MCIA card.
This description above is issued from
http://www.rainbow.com/tech/tech_notes/tn2021_a.html